Blacksmith Artisan Inset Stove Comment

Friday, January 13, 2012 0:26
% of readers think this story is Fact. Add your two cents.

(Before It's News)

.
Problems with the 
Blacksmith Artisan Inset Stove

I have just received a comment from a reader outlining their experience with the Blacksmith Artisan inset stove. It would seem their experience echoes the “Artisan” case I have documented.

I am beginning to believe that most if not all inset stoves have an over-rated output figure – through no fault of the manufacturer/vendor company, and perhaps more likely due to the methods of testing used by the test and certification companies.

I have contacts in the building trade, and the word out there is that inset stoves are nowhere as good as free standing stoves of similar rating.

I am inclined to think that it would be a good idea to mentally subtract say 33% from the certified output figures of inset stoves. This would give you a more realistic idea of the heat output. For instance, an inset stove boasting a certified 6Kw output, might perhaps more realistically achieve an actual 4Kw.

The Comment Letter

CK has left a new comment on your post “Blacksmith Stove Review Part 4 – Alert -“:

Tony,  I too am from Co.Kerry and have recently purchased the “Artisan” inset stove. My experience is similar to yours – disappointed with the product.

We opted for the inset based on the product description – “Fits into any 16″ or 18″ fireback”. Buyer beware – it does not!

We installed the inset and were so disappointed with its performance that we questioned the installation. We then removed the fireback and fully lined the chimney with a 6″ flexible flu liner (which was not needed for the inset stove) believing that this would maximise the output from the stove. Again, this was not the case.

We removed the stove again and had a registered Blacksmith installer (recommended by the retailer) install the stove. He completely sealed the chimney recess with fire cement before reinstalling. The heat output improved slightly,but still disappointing.

I agree with your findings – nowhere near the 5KW output as specified.

Our only option now is to contact the Blacksmith technical department and have someone call to inspect the stove. Is there anyway of measuring the heat output from the stove? Please let me know! 

A Partial Answer to above Question

To accurately and scientifically measure a stoves heat output into a room would require complex laboratory conditions and a lot of equipment.

However, that said, there is a fairly simple test you could do yourself at home. It would not be highly accurate, but it would establish roughly the heat output.

1.  The experiment would need to be carried out on two separate days with very similar weather conditions. It would require a calm day with little or no wind.  The outside temperature would need to be within a degree or so on both test days. For instance a calm day with outside temperatures of 10C.

2.  You would need to let the room go cold overnight to the same temperature on both test days. For instance the room should be at a starting temperature of say 17C on both occasions.

3. You will need to buy or borrow 3 electronic thermometers – these are not expensive and can be got on EBay for €5 – €7. They respond rapidly and are moderately accurate.

4.  You would have two sensors in different parts the room well away from the direct source of heat, – and one measuring the outside temperature.

5. You would need a 3Kw electric convection heater or use two heaters -one 1Kw and one 2Kw. These will provide a reference point. Remembers that electric heaters will reach temperature within a few minutes. A fire will need time to fully ignite, and an iron stove will take time to warm up – so the timing points will need to be offset by roughly 30 minutes, (Assuming an efficient and full ignition of the fire – you may need to add some more time until the fire is good and red)

6. On Test Day ONE.  (a) note the inside and outside temperatures. (b) Switch on the electric heater/s, (c) turn the thermostats up fully and (d) time how long it takes the room to reach a steady 23C.

7. On Test Day TWO. (a) Note the temperatures as before. (b) Light the fire using plenty of firelighter and kindling, and allow 30 minutes for the stove to heat up.  (c) Time how long it takes for the room to reach 23C.

This simple method will give you a ball park idea of the thermal output of the stove against a reference point. My bet is that the electric heaters will have the room up to temperature as quickly as the stove, even though their output is nearly half the rated output of the stove.

.
.

Read more at Sustainable Energy Author Ireland



Source:

Report abuse

Comments

Your Comments
Question   Razz  Sad   Evil  Exclaim  Smile  Redface  Biggrin  Surprised  Eek   Confused   Cool  LOL   Mad   Twisted  Rolleyes   Wink  Idea  Arrow  Neutral  Cry   Mr. Green

Top Stories
Recent Stories

Register

Newsletter

Email this story
Email this story

If you really want to ban this commenter, please write down the reason:

If you really want to disable all recommended stories, click on OK button. After that, you will be redirect to your options page.