Properly Representing Wind and Solar in Electricity Systems: Electricity Generated (Part II)

Tuesday, April 11, 2017 23:09
% of readers think this story is Fact. Add your two cents.

(Before It's News)

“If the purpose is to show fuel consumption by various fuels in electricity generation, the correct measure is not the electricity produced but the fuel consumed with the impact of erratic and unreliable wind and solar generation accounted for.”

This is the second post in a series reviewing Power magazine’s article on the International Energy Agency (IEA) paper, the recent World Energy Outlook. Part I dealt with installed capacity projections to 2040 and showed that this was a misleading measure. This post will show that in understanding fuel consumption, simply reporting the electricity produced is also misleading.

To illustrate the trends in fuels for electricity generation, the Power magazine article shows a more complex chart of electricity generation flows (compared to the installed capacity in Part I), reflecting such things as the net effect of plant closures and new plant construction to arrive at a result for 2040. This is a more realistic representation than installed capacity, but the graphic is not easy to re-create and understand.

Electricity Generated

Table 1 shows the information in a more comprehensible form. I do not know why the starting point changed to 2014 from 2015 in Part I.

Table 1 – Electricity Produced by Fuel from 2014 to 2040 as published in Power Magazine

Part II Table 1--Mar 24
On the surface, it appears that the 2040 total for other renewables (wind, solar, and biomass) are challenging coal and gas individually. The other renewables growth to 2040 appears impressive and considerably exceeds that of fossil fuels combined. However, the projected capacity factor for wind and solar is 31 percent, which is possibly somewhat generous.

What is wrong with this representation is that electricity generation (as well as costs and installed capacities) cannot be directly compared between non-dispatchable generation plants (wind and solar) and those that are dispatchable.[1] The reason is that non-dispatchable electricity is not reliable or useful by itself.

The other consideration is that electricity produced does not necessarily correspond to fuel consumption on a one-to-one basis. With wind and solar present this becomes a major consideration, because of the loss in efficiency experienced by fossil fuel plants balancing the unreliable and erratic nature of wind and solar electricity production to turn it into useful electricity supply. (I used the term ‘wasted energy’ and ‘friction’ to describe this previously.[2])

Ignoring this, unfortunately, appears to be the generally accepted practice in dealing with the relative characteristics of electricity generation technologies. Why? I assume it is because this is a complex and not well understood matter, and it is possibly commonly accepted that it can be ignored.

So, if the purpose is to show fuel consumption by various fuels in electricity production, the correct measure is not the electricity produced but the fuel consumed with the impact of erratic and unreliable wind and solar generation accounted for.

Fuel Consumption in Electricity Generation

Table 2 shows the primary energy consumption, converted from TWh to Mtoe (million tons of oil equivalent), assuming conversion efficiencies to electricity are 40 percent for all primary energy sources,.[3] TWh could have continued to be used, but this conversion is done primarily to clearly differentiate this from electricity produced.

Table 2 – Primary Energy Consumption by Fuel in Mtoe

Part II Table 2 (1)--Mar 25 2017

This sets the stage for the necessary adjustment to energy consumption, reflecting wasted energy.

Wasted Energy Considerations

In Part I yesterday, it was shown Capacity Factors alone did not cover all the considerations necessary to make direct comparisons with dispatchable generation plants. In the capacity case, and Capacity Credit had to be applied instead.

In this case, the effect of wasted energy must be accounted for. The wasted energy is due to the need to continuously balance erratic wind and solar to produce steady, reliable, and hence useful, electricity. This must account for the dynamic minute-by-minute operation (dynamic efficiency impact) forced on wind and solar balancing plants, in addition to any reduced efficiency due to part loading alone (static efficiency impact) as described in note 2.

If there is no efficiency loss due to part loading and short-term dynamic loading, then there is no increase in fossil fuel consumption from that shown in Table 2 even at the decreased loading of fossil fuel plants with wind and solar present. However, if there is decreased efficiency, for the reasons described above plus more frequent plant start-up/shut-down, then the fossil fuel consumption will likely increase substantially because of the efficiency losses experienced. This could extend to no savings in fossil fuel consumption with wind and solar present, or even more fossil fuel consumption.[4]

The assumptions used in establishing real primary fuel use here are:

  • The effect of the reduced efficiency is taken to be based on zero fossil fuel savings, so the fossil fuel plants will experience increased fuel consumption to the level they would have experienced in generating the electricity replaced by wind and solar energy, which is the equivalent of the primary energy consumption of wind and solar. So, this amount is added to that for the fossil fuels, which increases the overall energy consumption total in Table 2.
  • As gas will likely be the main wind and solar balancing technology, the added primary energy consumption will be allocated to coal and gas in the ratio of one-third to coal and two-thirds to gas. In the calculation, the biomass component is not included in the increase to other fossil fuel energy consumption.
  • Hydro is a candidate for balancing wind and solar but a less useful one because of their short term erratic behaviour, which is a major source of efficiency loss.

Table 3 shows the results. Intermediate levels of efficiency loss can easily be determined by interpolating between the differences in Tables 2 and 3.

Table 3 – Takes into Account the Reduced Efficiency Imposed on Fossil Fuel Plants by Wind and Solar

Part II Table 3

This notably reduces the total of wind and solar (representing about 90% of Other Renewables) relative to the fossil fuels such that these are not challenging fossil fuels to any significant degree. In terms of the change from 2014 to 2040 wind and solar do not dominate as before in total or combined fossil fuel consumption.This is more likely representative of fossil fuel consumption than that shown in Table 2. What Table 3 says is that, although no more electricity is generated, more fossil fuel is consumed because of the increased inefficiencies of the fossil fuel generation plants due to the presence of wind and solar.

This means that wind and solar can be removed from Table 3, returning the totals to those shown in Table 2, and:

  • No additional capacity is required as the wasted energy due decreased efficiencies with wind and solar present can be replaced by the existing fossil fuel plants. This was shown graphically in Part I, Figures 5 and 6.
  • There will be no increased emissions from fossil fuel generation plants because no additional fossil fuels are consumed.

Impact on Dispatchable Generation Plant Capacity Factor

Capacity factor is the ratio of electricity produced over time (usually a year or years) to the maximum that the installed capacity can produce for the same period. It is normal for an electricity system without wind and solar to have an overall capacity factor of about 50 percent. At peak loads all the installed capacity is called on, which includes meeting demand and providing a range of services to ensure system reliability, including reserves. This should be about 20 percent of total installed capacity.

Table 4 shows the impact on the capacity factors of coal, gas, nuclear and hydro with and without wind and solar present.

Table 4 – Capacity Factor Comparison with and without Wind and Solar

Part II Table 4

Note the improvement in global capacity factors without wind and solar present in electricity systems, especially in 2040.

Conclusions

Comparisons cannot be directly made between electricity produced by non-dispatchable generation plants (wind and solar) and dispatchable, reliable generation plants.

Fuel consumption should not be assumed to be equivalent to electricity produced.

The main take away from the Power magazine article is that renewables (especially wind and solar) will strongly take the lead over coal and gas through 2040. The article claims that the “coal boom is over” and the outlook for gas is “dim.” Taking into account the decreased efficiencies in fossil fuel plants with wind and solar present, these are very questionable statements.

————

[1] See DOE/EIA document http://www.eia.gov/outlooks/aeo/pdf/electricity_generation.pdf. Note comments in the second paragraph on pages 2 and 4 and in the following tables that wind and solar are shown separately.

[2] See https://www.masterresource.org/energy-sources/primary-energy-electricity-ii/, under heading ‘Wasted Energy from Wind, Solar Forcing”. Further to the driving a car on a highway illustration, add the consideration of stop/start/idling in rush hour traffic in major cities.

[3] This appears to be a very rough approach, but closer examination will likely show difficulties in setting individual efficiencies on a global basis and accounting for aging generation plants, especially wind and solar. This more complex approach will not likely materially change overall results and could be equally questioned in detail. For more information see https://www.masterresource.org/energy-sources/primary-energy-electricity-ii/, endnote 1.

[4] It is reported that KEMA, an international energy consulting firm based in the Ne therlands, showed that the cycling of fossil fuel plants from a normal full load to reduced load and back to normal over one hour resulted an increase of more than 1% fuel consumption over operating normally for the same period. See paragraph 4.a Cycling at http://www.clepair.net/windSchiphol.html. This means that this limited cycling of fossil fuel plants increases emissions over their steady state condition, and it is reasonable to expect that continuous frequent cycling within the hour would increase this even more. This cycling already occurs in load following in the short term and the same, but to a greater degree, when balancing wind. Note that when cycling less electricity is produced over the hour than normal, steady state. This strongly suggests that the fuel consumption and emissions increases with the presence of wind. So simply relating emissions to electricity generation with simplified efficiency assumptions is a questionable approach to analyzing wind emissions performance.

The post Properly Representing Wind and Solar in Electricity Systems: Electricity Generated (Part II) appeared first on Master Resource.

Report abuse

Comments

Your Comments
Question   Razz  Sad   Evil  Exclaim  Smile  Redface  Biggrin  Surprised  Eek   Confused   Cool  LOL   Mad   Twisted  Rolleyes   Wink  Idea  Arrow  Neutral  Cry   Mr. Green

Top Stories
Recent Stories

Register

Newsletter

Email this story
Email this story

If you really want to ban this commenter, please write down the reason:

If you really want to disable all recommended stories, click on OK button. After that, you will be redirect to your options page.